46-50 Installation and User Guide V1.0
46-50 FOUR ZONE
INTEGRATED
MIXER AMPLIFIER
Installation and User Guide
0
1
SOURCESOURCESOURCESOURCE
MUSIC LEVELMUSIC LEVELMUSIC LEVELMUSIC LEVEL
MIC 2
MIC 1
LEVEL
1
2
3
4
5
6
HFLF
0
1010
10
0
-
dB
ZONE 1 MUSIC EQ
CLIP
MIC 2
MIC 1
LEVEL
1
2
3
4
5
6
HFLF
0
1010
10
0
-
dB
ZONE 2 MUSIC EQ
CLIP
MIC 2
MIC 1
LEVEL
1
2
3
4
5
6
HFLF
0
1010
10
0
-
dB
ZONE 2 MUSIC EQ
CLIP
MIC 2
MIC 1
LEVEL
1
2
3
4
5
6
HFLF
0
1010
10
0
-
dB
ZONE 2 MUSIC EQ
CLIP
ZONE 1 ZONE 2 ZONE 3 ZONE 4
4 ZONE 50W INTEGRATED
MIXER AMPLIFIER
Page view 0
1 2 3 4 5 6 ... 27 28

Summary of Contents

Page 1 - MIXER AMPLIFIER

46-50 Installation and User Guide V1.046-50 FOUR ZONE INTEGRATED MIXER AMPLIFIERInstallation and User Guide01SOURCESOURCESOURCESOURCEMUSIC LEVELMUSI

Page 2

46-50 Installation and User Guide V1.010Block DiagramMUSICEQMUSICVCASPEAKERMODULELINE 6LINE 5LINE 4LINE 3LINE 2LINE 1LINE 6PRIORITYRELEASETIMEMUSICEQM

Page 3 - IMPORTANT SAFETY INSTRUCTIONS

46-50 Installation and User Guide V1.0 11Front panel description01SOURCESOURCESOURCESOURCEMUSIC LEVELMUSIC LEVELMUSIC LEVELMUSIC LEVELMIC 2MIC 1LEVEL1

Page 4 - Contents

46-50 Installation and User Guide V1.012Rear panel description2 22 11 15 1316213 5 6 6 10 8 14 7 1254 9 91. LINE 1 to LINE 6 – six pairs of RCA (p

Page 5

46-50 Installation and User Guide V1.0 13INSTALLATION Hardware considerationsThe 46-50 Mixer Amplier is built in a 2U-high 19” rack mount enclosure.

Page 6 - SAFETY INFORMATION

46-50 Installation and User Guide V1.014and some designs require different wiring protocols to others, but to connect only the ‘hot’ and ‘screen’ to t

Page 7 - OVERVIEW

46-50 Installation and User Guide V1.0 15Connecting a PM1 paging micThe PM 1 is a simple, passive paging microphone suitable for situations where an

Page 8 - Optional system components

46-50 Installation and User Guide V1.016Connecting an RSL-6 Series remote control plateWire the remote control plate as shown below. Twin-and-s

Page 9 - PM Series microphones

46-50 Installation and User Guide V1.0 17Speaker outputs (100/70 V-line operation)The 46-50 may be converted for 100/70 V-line operation by the use

Page 10 - Block Diagram

46-50 Installation and User Guide V1.018SETTING UP & OPERATIONMusic InputsGain & levelTo avoid dramatic changes in volume when switching betwe

Page 11 - Front panel description

46-50 Installation and User Guide V1.0 19Zone outputsIn normal operation, the music level in each zone will be set by the front panel M

Page 12 - 3 5 6 6 10 8 14 7 1254 9 9

46-50 Installation and User Guide V1.02WARNING:To reduce the risk of re or electric shock, do not expose this appliance to rain or moisture.CAUTION:U

Page 13 - INSTALLATION

46-50 Installation and User Guide V1.020Line 6 priorityIt may sometimes be necessary for one music input to have priority over all the others; for exa

Page 14 - Microphone input

46-50 Installation and User Guide V1.0 21OPTIONS AND ADDITIONAL INFORMATIONRL-1 and RSL-6 Series remote control plates – general considerationsCloud R

Page 15 - Music control

46-50 Installation and User Guide V1.022Music sourceMusic source for a zone may be controlled by applying various DC voltages of between 0 an

Page 16 - Speaker outputs (Lo-Z)

46-50 Installation and User Guide V1.0 236. Plug the 2-pin connectors on the other end of the ying lead assembly onto the corresponding headers

Page 17 - Music Mute

46-50 Installation and User Guide V1.024APPENDIXPCB jumper locationsThe 46-50 has various internal jumpers, the setting of which may require alteratio

Page 18 - SETTING UP & OPERATION

46-50 Installation and User Guide V1.0 25Table of internal jumpers and default settingsThe table below lists each jumper and its purpose, together wit

Page 19 - Priorities

46-50 Installation and User Guide V1.026EMC considerationsThe Cloud 46-50 fully conforms to the relevant electromagnetic compatibility (EMC) standards

Page 20 - Line 6 priority

46-50 Installation and User Guide V1.0 27GENERAL SPECIFICATIONSPower input 230 V ±5% (115 V ±5% available)Fuse rating 230 V: T3.15AH; 115 V: T6.3AHFus

Page 21 - Music level

Cloud Electronics Limited140 Staniforth RoadShefeld S9 3HFEnglandTel: +44 (0)114 244 7051Fax: +44 (0)114 242 5462email: [email protected]: www.clou

Page 22 - Fitting loudspeaker EQ cards

46-50 Installation and User Guide V1.0 3IMPORTANT SAFETY INSTRUCTIONS1. Read these Instructions.2. Keep these Instructions.3. Heed all Warnings.4.

Page 23 - Fitting the EQ security cover

46-50 Installation and User Guide V1.04ContentsIMPORTANT SAFETY INSTRUCTIONS ...

Page 24 - APPENDIX

46-50 Installation and User Guide V1.0 5SETTING UP & OPERATION ...

Page 25

46-50 Installation and User Guide V1.06SAFETY INFORMATIONSafety Notes regarding Installation• Do not expose the unit to water or moisture.• Do not e

Page 26 - TECHNICAL SPECIFICATIONS

46-50 Installation and User Guide V1.0 7OVERVIEWIntroductionThank you for purchasing this Cloud Multi-Zone Mixer Amplier. We are condent that

Page 27 - GENERAL SPECIFICATIONS

46-50 Installation and User Guide V1.08Optional system componentsThe following components may form part of the audio system and may be ordered separat

Page 28

46-50 Installation and User Guide V1.0 9PM Series microphonesCloud PM Series paging microphones may be connected directly to the 46-50 using MI